Oldcastle-buildingenvelope HP-175 User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
MARK LOCATION OF EACH
GLAZING CLIP PRIOR TO
INSTALLING FACE CAPS.
HP-3 6 TE MPORARY
CLIPS. S LIDE ONTO
GLAZING CLIPS.
HP-17
SETTING
BLOCK
HP-10451
WHEN INSTALLING FACE
CAPS USE DEADB LOW
HAMMER AND STRIKE CAPS
AT LOCATIONS OF GLAZING
CLIPS ONLY.
HP-10453 FACE CAP
INSTALL VERTICAL CAPS
FIRST, THEN HORIZONTALS.
GLASS SIZING
HP-175 = D.L.O. + 3/4"
HP-225 = D.L.O. + 1"
NHP-5A GASKETS.
CUT HORIZONTAL
GASKETS D. L.O.
+ 1/4" PER FOOT.
NHP-5A GASKETS.
VERTICAL GASKETS
TO RUN THROUGH AND
ADD 1/4" PER FOOT.
HP175-FP-43 BRIDGE
MODIFY TO BUTT
AGAINST MULLION
& SEA L
SEE CHART BE LOW
FOR EXTRUSION NUMBERS.
INT.MULL COVERS
HP-175 HP-225
HP-10454 5 1/4"
HP-10455 6" HP-20074 6 1/4"
HP-10456 6 3/4" HP-20075 7"
INSTALLATION NOTE:
REFERENCE SHEET 9 & 10 FOR
ADDITIONAL DIVERTER INSTALLATION
AND SHEETS 12 & 13 FOR GLAZING
INFORMATION USING CONTINUOUS
DIVERTERS. REFERENCE SHEET 11 FOR
INFORMATION FOR INTEGRAL DIVERTER
INTALLATIONS AND 14 & 15 FOR
GLAZING WITH INTEGRAL DIVERTERS.
CAUTION:
BE CERTAIN THAT GLASS IS P LACED
FIRMLY AGAINST INTERIOR GASKET BEF ORE
SETTING ON BLOCKS. GLASS BREAKAGE CAN
OCCUR AT OR NEAR SETTING B LOCKS DUE
TO THE WEIGHT OF THE GLASS N OT
ALLOWING THE GLASS T OMOVE TOWARD
INTERIOR GASKET. LUBRICATING THE TOP
OF THE SETTING BLOCK WILL HELP INSURE
PROPER SETTING OF GLASS.
OUTSIDE 90° MULLION
DIVERTER & GLAZING DETAIL
H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L
25



Page view 24
1 2 ... 20 21 22 23 24 25

Comments to this Manuals

No comments