GLASS JOINT
(NO SP LICE IN CAP)
NOTE: LEAVE SPACE IN
GASKET AT BOTTOM FOR
WEEPAGE
WITH SEALANT,MARRY WEATHER
SEAL TO GASKET AT TOP
G LASS JOINT
(SP
L
ICE IN CAP)
MARRY WEATHER SEAL
@ GLASS TO WEATHER
SEAL @ FACE CAP
NOTE: LEAVE SPACE IN
GASKET & SEALANT AT
BOTTOM FOR WEEPAGE
WEATHER SEAL
OPEN CELL
BACKER ROD
WHEN INSTALLING FACE CAPS
USE DEADBLOW HAMMER AND
IMPACT CAPS AT LOCATIONS
OF GLAZING CLIPS ONLY.
GASKET N OTE:
PRE-CUT NHP-5A GASKETS F OR FACE
CAPS, ALLOWING 1/4" PER FOOT
ADDITIONAL LENGTH FOR SHRINKAGE.
SEE DETAI L BELOW FOR INSTRUCTIONS
ON GASKET CUT LENGTH AT UNDERSIDE
OF HORIZONTAL.
GLASS SIZING
HEIGHT = D.L.O. + 3/4"
WIDTH = D.L.O. + 1 1/4"
BUTT GLAZE MULLI0N
GLAZING DETAILS