CUT NHP-5A GASKET 3/4" SHORT
ON BOTTOM SIDE OF HORIZONTAL
FACE CAPS AT BOTH ENDS.
WHEN INSTALLING FACE CAPS
USE DEADBLOW HAMMER AND
STRIKE CAPS AT LOCATIONS
OF GLAZING CLIPS ONLY.
INSTALL VERTICAL CAPS
FIRST, THEN HORIZONTALS.
3/4"
GLASS SIZING
HP-175 = D.L.O. + 3/4"
HP-225 = D.L.O. + 1"
GASKET NOTE:
PRE-CUT NHP-5A GASKETS FOR
FACE CAPS, ALLOWING 1/4" PER FOOT
ADDITIONAL LENGTH FOR
SHRINKAGE. SEE DETAIL BELOW FOR
INSTRUCTIONS ON GASKET CUT
LENGTH AT UNDERSIDE OF
HORIZONTALS.
CAP INSTALLATION NOTE:
TO INSTALL FACE CAPS, LOCATE
CAP ONTO CLIPS AT EACH END.
PRESS FIRMLY AGAINST CAP
UNTIL GASKET IS COMPRESSED
AGAINST GLASS AND STRIKE AT
PREVIOUSLY MARKED
LOCATIONS OF GLAZING CLIPS.
WHEN INSTALLED PROPERLY
CAPS SHOULD RESIST ROTATION.
INTEGRAL DIVERTER HORIZONTAL
GLAZING DETAILS