Page view 29
DETAIL "A"
DETAIL "B"
15°
SEAL CORNERS AT
GLAZING TRACK PRIOR
TO SETTING GLASS.
MITER HORIZONTAL GASKET TO VERTICAL GASKET
INSIDE GLAZED SYSTEMS
GLAZING GUIDELINES
SEAL CORNERS GASKET
RACE AT WATER
DIVERTER.
1) REMOVE GASKETS FROM ROLL AND ALLOW TO RELAX OVERNIGHT.
ALL GASKETS TO BE CUT D.L.O. + 1/4" PER FOOT.
2) VERTICAL GASKETS RUN THRU HORIZONTAL GASKETS.
HORIZONTAL GASKETS SHOULD BE MITERED ON ENDS AS SHOWN IN DETAIL “A”.
3) INSTALL EXTERIOR GASKETS PRIOR TO GLAZING. CORNERS OF EXTERIOR GASKETS TO BE SET IN
SEALANT (DTL."B") AND CORNERS SEALED JUST PRIOR TO SETTING GLASS (DTL."A").
NOTE: CLEAN GASKETS AND SURFACES WITH ISOPOPYL ALCOHOL PRIOR TO
SEALING CORNERS.
4) LOCATE SETTING BLOCKS AT EITHER 1/4 POINTS OR 1/8 POINTS, DEPENDENT ON SIZE OF GLASS.
6) GLAZE OPENINGS FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS IN HORIZONTAL ABOVE,
AFTER LITE BELOW IS IN POSITION
7) WATER DIVERTERS MUST BE LOCATED ON EACH END OF HORIZONTALS
AND SET IN SEALANT.
8) WHEN INSTALLING GLASS: FIRST, WET TOP OF SETTING BLOCK WITH SOAPY WATER.
ONCE GLASS IS SET IN PLACE, PUSH GLASS AGAINST GASKET AT SETTING BLOCK AREA.
FAILURE TO DO SO MAY CAUSE DIAGONAL CRACKS TOWARDS SETTING BLOCKS DUE TO
GLASS BENDING WHILE INSTALLING GASKET(S) IN CORNERS.
30



S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L
5) GLASS BITE AT TYPICAL HORIZONTAL & VERTICAL MEMBERS IS 7/16”. AT SSG VERTICAL 3/4”.
Page view 29